Chapter 6 Fastening Operation
PAGE 6-30
•If the rate start torque (angle) cannot be detected during fastening operation, the rate judgment
will not be performed.
•Under the following conditions, the torque (angle) at the end of fastening is judged as the rate
end torque (angle).
•If the set values are set so that rate start torque (angle) > rate end torque (angle).
•If the rate end torque (angle) cannot be detected during the fastening operation.
.
When the increase in angle from the measurement start point to the end point is “0” deg, the
operation varies depending on the firmware version.
·
Before ver1.304: The rate calculation becomes "0" and rate is not judged
·
Ver1.305 or later: The rate calculation becomes the maximum and the rate judgment is rate
high NG
●
FUSION/HFC3000 Fastening Parameter (Rate) Correspondence Table
FUSION
Fastening Parameter
HFC3000
Fastening Parameter
Function
17 Threshold Torque
112 Rate 1 Start Torque
The torque value sets the start point of
measurement of torque rate 1.
15 1st Torque
(1st Rate End Torque)
113 Rate 1 End Torque
The torque value sets the end point of
measurement of torque rate 1.
1E 2nd Rate Start Torque
114 Rate 2 Start Torque
The torque value sets the start point of
measurement of torque rate 2.
18 CROS Torque
(2nd Rate End Torque • 3rd
Rate End Torque)
115 Rate 2 End Torque
The torque value sets the end point of
measurement of torque rate 2.
116 Rate 3 Start Torque
The torque value sets the start point of
measurement of torque rate 3.
13 Standard Torque
(3rd Rate End Torque)
117 Rate 3 End Torque
The torque value sets the end point of
measurement of torque rate 3.
208 Rate 1 Start Angle
The angle value sets the start point of
measurement of torque rate 1.
23 1st Angle
(1st Rate End Angle)
209 Rate 1 End Angle
The angle value sets the end point of
measurement of torque rate 1.
26 2nd Rate Start Angle
210 Rate 2 Start Angle
The angle value sets the start point of
measurement of torque rate 2.
24 CROS Angle
(2nd Rate End Angle • 3rd Rate
Start Angle)
211 Rate 2 End Angle
The angle value sets the end point of
measurement of torque rate 2.
212 Rate 3 Start Angle
The angle value sets the start point of
measurement of torque rate 3.
27 3rd Rate Start Angle
22 Standard Angle
(3rd Rate End Angle)
213 Rate 3 End Angle
The angle value sets the end point of
measurement of torque rate 3.
Caution
Содержание Handheld Nutrunner HFC3000
Страница 2: ...www fec usa com Copyright 2017 FEC AUTOMATION SYSTEMS All Rights Reserved ...
Страница 14: ...Notes ...
Страница 15: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 21: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 28: ...Chapter 2 Specifications PAGE 2 8 Blank Page ...
Страница 29: ...Chapter 3 Sysytem Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 36: ...Chapter 3 System Description PAGE 3 8 Memo ...
Страница 37: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation Wiring 4 ...
Страница 67: ...Chapter 5 Power Up and Operational Tests PAGE 5 1 Chapter 5 Power Up and Operational Tests 5 ...
Страница 71: ...Chapter 6 Fastening Operation PAGE 6 1 Chapter 6 Fastening Operation 6 ...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 ...
Страница 169: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 ...
Страница 181: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 1 Chapter 9 Fieldbus I O Interfaces 9 ...
Страница 207: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 27 9 3 2 Description of the hardware RUN LED ERROR LED CC Link Connector ...
Страница 229: ...Chapter 9 Fieldbus I O Interfaces PAGE 9 49 Blank Page ...
Страница 230: ......
Страница 231: ......