Glossary
Power Blazer
821
Generic Framing Procedure (GFP)
Payload Information Field
The payload area (also referred to as payload information field)
contains the framed client signal. This variable-length field may include
from 0 to 65,535 – X octets, where X is the size of the payload header
(including the extension header, if present) and the payload FCS field
(if present).
Figure
on page 814 shows the GFP-T and
GFP-F frame structures. As shown, Both GFP-T and GFP-F frame types
share a common core header, payload header, and payload FCS
(optional), and they differ in the way in which the client is mapped into
this payload area.
Payload FCS (pFCS)
This is an optional four-octet-long frame-check sequence. It
contains a CRC-32 check sequence that is designed to validate the
entire content of the payload area. The FCS field presence is
signalled by the PFI bit located in the Type field of the payload
header. The FCS does not correct any errors; it just indicates the
presence of error(s).
In GFP-F, the transmitter encapsulates one entire frame of the
client data into one GFP frame. In this case, the basic frame
structure of a GFP client frame is used, including the required
payload header.
In GFP-T, however, rather than buffering an entire client-data
frame, the individual characters of the client signal are demapped
from the client block codes and then mapped into periodic
fixed-length GFP frames. The transparent GFP client frame uses
the same structure as the frame-mapped GFP, including the
required payload header.
Содержание Power Blazer 88200NGE
Страница 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Страница 14: ......
Страница 20: ......
Страница 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Страница 65: ...Test Setup Test Applications Power Blazer 55 OTN BERT OTU4 for 88200NGE 890 890NGE OTU4 for 88260...
Страница 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Страница 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Страница 620: ......
Страница 726: ......
Страница 752: ......
Страница 756: ......
Страница 768: ......
Страница 789: ...Glossary Power Blazer 779 10G Ethernet Client The following figure presents a typical network application...
Страница 803: ...Glossary Power Blazer 793 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...
Страница 847: ...Glossary Power Blazer 837 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Страница 886: ...0 5 1 5 48 5 0 176 W d y K y K D...