Test Results
404
88000 Series
Alarms/Errors Overview
E4
Alarms
Note:
Only AIS is available when the framing is set to Unframed.
AIS
(Alarm Indication Signal)
RX
: An unframed all-ones signal is received.
LOF
(Loss Of Frame)
RX
: Four consecutive incorrect frame alignment signals is received.
RAI
(Remote Alarm Indication)
RX
: Bit 13 of a framed E4 is set to “1”.
Errors
FAS
(Frame Alignment Signal)
RX
: Bits 1 to 12 of the first frame differ from 111110100000.