QX1000 Manual II: Administrator's Guide
Administrator’s Menus
QX1000; (SW Version 5.3.x)
40
which stays unchanged when the device switches its mode (from master to backup or vice versa). The configuration and voice data synchronization
daemon uses this IP address to communicate with the second QX1000.
Redundant Device Virtual IP Address
text fields require an alternate IP address of the LAN interface of the second QX1000.
Synchronization Interval
text field requires the period of time (in seconds) between two consecutive configuration and voice data synchronizations
from master to backup device.
Swap Master Device
button is used for manual swapping of functionality of master and backup devices. This action will result in rebooting the
current master. After rebooting the current master device will start running in a backup mode. Switching the backup to master starts all applications
on QX1000 and causes all IP phones to reboot. The swapping takes around 1 minute however another 1-3 minutes are required in order to reboot all
the IP phones connected to redundant system. If backup device before swapping was in passive mode then after swapping the master will start
running as backup in passive mode, otherwise if it was in active mode then master will start running as backup in active mode.
Download system logs
link is only present on backup device and is used to download system logs to the local PC as a *.tar archive file. These logs