You can skip positions and you can repeat process variables.
Table 7-1: Default configuration for display variables
Display variable
Process variable assignment
Display Variable 1
Mass flow rate
Display Variable 2
Mass total
Display Variable 3
Volume flow rate
Display Variable 4
Volume total
Display Variable 5
Density
Display Variable 6
Temperature
Display Variable 7
Drive gain
Display Variable 8
None
Display Variable 9
None
Display Variable 10
None
Display Variable 11
None
Display Variable 12
None
Display Variable 13
None
Display Variable 14
None
Display Variable 15
None
Configure a two-line display screen
Display
Menu
>
Configuration
>
Display Settings
>
Display Variables
>
2-Value View
ProLink III
Device Tools
>
Configuration
>
Transmitter Display
>
Display Variables
>
2 PV Screen Slot #
X
Field Communicator
Configure
>
Manual Setup
>
Display
>
Display Variables
>
Display: Two-Variable View
You can configure one display screen to show two process variables at a time. For each of these process
variables, the current value and the measurement is shown.
The two-line display screen operates like one of the basic 15 screens. You can use
⌄
and
⌃
to scroll to it. If Auto
Scroll is enabled, the two-line screen will be the last screen in the cycle.
7.1.3 Configure the number of decimal places (precision) shown on
the display
Display
Menu
>
Configuration
>
Display Settings
>
Decimals on Display
ProLink III
Device Tools
>
Configuration
>
Transmitter Display
>
Display Variables
>
Decimal Places for x
Field Communicator
Configure
>
Manual Setup
>
Display
>
Decimal Places
Configure device options and preferences
Configuration and Use Manual
March 2019
MMI-20025166
120
Micro Motion Model 5700 Transmitters with Configurable Outputs