h) Choose
End
.
2. Test the Frequency Output(s).
a) Choose
Service Tools
>
Simulate
>
Simulate Outputs
and select the frequency output to test.
•
Channel B = Frequency Output 2
•
Channel C = Frequency Output 1
•
Channel D = Frequency Output 2
Note
If you have configured both Channel B and Channel D as Frequency Output 2, be sure to test
both loops.
b) Select the frequency output level.
c) Press
OK
.
d) Choose
End
.
3. Test the Discrete Output(s).
a) Choose
Service Tools
>
Simulate
>
Simulate Outputs
and select the discrete output to test.
•
Channel B = Discrete Output 1
•
Channel C = Discrete Output 2
•
Channel D = Discrete Output 3
b) Choose
Off
.
c) Verify the signal at the receiving device.
d) Press
OK
.
e) Choose
On
.
f) Verify the signal at the receiving device.
g) Press
OK
.
h) Choose
End
.
4. Test the Discrete Input.
a) Set the remote input device to ON.
b) Choose
Service Tools
>
Variables
>
Inputs/Outputs
and read the state of the discrete input.
•
Channel C = Discrete Input 1
•
Channel D = Discrete Input 2
c) Set the remote input device to OFF.
d) Choose
Service Tools
>
Variables
>
Inputs/Outputs
and read the state of the discrete input.
•
Channel C = Discrete Input 1
Troubleshooting
Configuration and Use Manual
March 2019
MMI-20025166
296
Micro Motion Model 5700 Transmitters with Configurable Outputs