Verify that the host is writing to the correct register in memory, using the correct data type.
5.1.4 API tables supported by the API referral application
The API tables listed here are supported by the API referral application.
Table 5-1: API tables, process fluids, measurement units, and default reference values
Process fluid
API tables
(calculations)
Referred density
(API): unit and
range
Default
reference
temp
Default
reference
pressure
API standard
Referred
density
CTL or
CTPL
Generalized crude
and JP4
5A
6A
Unit: °API
Range: 0 to 100 °API
60 °F
0 psi (g)
API MPMS 11.1
23A
24A
Unit: SGU
Range: 0.6110 to
1.0760 SGU
60 °F
0 psi (g)
53A
54A
Unit: kg/m
3
Range: 610 to
1075 kg/m
³
15 °C
0 kPa (g)
Generalized
products (gasoline,
jet fuel, aviation fuel,
kerosene, heating
oils, fuel oils, diesel,
gas oil)
5B
6B
Unit: °API
Range: 0 to 85 °API
60 °F
0 psi (g)
API MPMS 11.1
23B
24B
Unit: SGU
Range: 0.6535 to
1.0760 SGU
60 °F
0 psi (g)
53B
54B
Unit: kg/m
3
Range: 653 to
1075 kg/m
³
15 °C
0 kPa (g)
Liquids with a
constant density
base or known
thermal expansion
coefficient
N/A
6C
Unit: °API
60 °F
0 psi (g)
API MPMS 11.1
N/A
24C
Unit: SGU
60 °F
0 psi (g)
N/A
54C
Unit: kg/m
³
15 °C
0 kPa (g)
Lubricating oils
5D
6D
Unit: °API
Range:
−
10 to
+40 °API
60 °F
0 psi (g)
API MPMS 11.1
23D
24D
Unit: SGU
Range: 0.8520 to
1.1640 SGU
60 °F
0 psi (g)
53D
54D
Unit: kg/m
³
Range: 825 to
1164 kg/m
³
15 °C
0 kPa (g)
NGL (natural gas
liquids) and LPG
(liquid petroleum
gas)
23E
24E
Unit: SGU
60 °F
0 psi (g)
API MPMS 11.2.4
53E
54E
Unit: kg/m
³
15 °C
0 psi (g)
Configuration and Use Manual
Configure process measurement applications
MMI-20025166
March 2019
Configuration and Use Manual
69