Procedure
Set
Pressure Measurement Unit
to the desired unit.
•
Default: psi
4.7.1 Options for Pressure Measurement Unit
The transmitter provides a standard set of measurement units for
Pressure Measurement Unit
. Different
communications tools may use different labels for the units. In most applications, set
Pressure Measurement
Unit
to match the pressure measurement unit used by the remote device.
Unit description
Label
Display
ProLink III
Field Communicator
Feet water @ 68 °F
ftH2O @68°F
Ft Water @ 68°F
ftH2O
Inches water @ 4 °C
inH2O @4°C
In Water @ 4°C
inH2O @4DegC
Inches water @ 60 °F
inH2O @60°F
In Water @ 60°F
inH2O @60DegF
Inches water @ 68 °F
inH2O @68°F
In Water @ 68°F
inH2O
Millimeters water @ 4 °C
mmH2O @4°C
mm Water @ 4°C
mmH2O @4DegC
Millimeters water @ 68 °F
mmH2O @68°F
mm Water @ 68°F
mmH2O
Millimeters mercury @ 0 °C
mmHg @0°C
mm Mercury @ 0°C
mmHg
Inches mercury @ 0 °C
inHg @0°C
In Mercury @ 0°C
inHg
Pounds per square inch
psi
PSI
psi
Bar
bar
bar
bar
Millibar
mbar
millibar
mbar
Grams per square centimeter
g/cm2
g/cm2
g/Sqcm
Kilograms per square centimeter
kg/cm2
kg/cm2
kg/Sqcm
Pascals
Pa
pascals
Pa
Kilopascals
kPA
Kilopascals
kPa
Megapascals
mPA
Megapascals
MPa
Torr @ 0 °C
torr
Torr @ 0°C
torr
Atmospheres
atm
atms
atm
4.8 Configure Velocity Measurement Unit
Display
Menu
>
Configuration
>
Process Measurement
>
Velocity
>
Units
ProLink III
Device Tools
>
Configuration
>
Process Measurement
>
Velocity
>
Unit
Field Communicator
Configure
>
Manual Setup
>
Measurements
>
Approximate Velocity
>
Velocity Unit
Configuration and Use Manual
Configure process measurement
MMI-20025166
March 2019
Configuration and Use Manual
51