CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
80 / 144
EN
6.3.3.6.
Timer
In this section, you can set the parameters of automatic arming and disarming the
partition.
You can set the time for arming/disarming and you can independently turn on and off
each time. By clicking the check box, located on the left side of the time field, you can
activate/deactivate the time. If auto-arming/disarming is off, the time field is grayed out.
When the partition is automatically armed / disarmed, to the monitoring station is sent a
report that was done by the user with the number 253.
At the time of auto-arming, exit time is starting. During the exit time, the user may at any
time to stop arming with the code. Then the system will not be armed.
If there is a fault in the system, they not prevent arming (like remote control and remote
command).
For each input zone is available „Interlocking after time for exit” option. If this option is
active, in the case of arming with violated zone, after time for exit, will be generated
event about blocked zone. Zone blocking will continue until partition disarming (see item
6.3.1.3. Interlocking).
When set to the same time arming and disarming, the system will first be disarmed and
then immediately armed.
If the time in the device is set forward (eg. when the time is changed to Daylight saving
time), and arming or disarming time is in the period which has been ommited, then the
hour will be not used. Eg. If the auto-arming time is set to 2:30, and time was changed
forward from 2:00 to 3:00, the control panel will not arm.
Times of arming and disarming can also configure by remote command via GPRS or SMS.