CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
69 / 144
EN
6.1.3.5.
Sequence of connections with servers
If you check this box, the equipment will try to establish a connection with primary
server, irrespectively of the secondary server parameters set (in particular, the number of
connection attempts).
6.1.4.
Secondary Server Parameters
6.1.4.1.
Server IP Address
It is the IP address of a secondary (redundant) monitoring system receiver (OSM.Server)
or a computer on which “Communication server” software is installed, e.g. 89.130.125.82.
The address can be given as a server’s domain name, e.g. monitor.gprs.com. In such a
case at least one DNS server address is required.
6.1.4.2.
Server port
It defines a port which was dedicated in the server for the receipt of data from the
equipment.
6.1.4.3.
Interval between subsequent attempts
If the equipment cannot connect with primary server, after the defined number of
attempts it will initiate the procedure of connecting with a secondary server. Here you can
define an interval (in seconds) after which the equipment will retry to connect with a
server, in case the previous attempt was unsuccessful.
6.1.4.4.
Number of attempts of establishing connection with a server
You can define how many times the equipment will try to connect with a secondary
server. In case of subsequent unsuccessful attempts, after the defined number of
attempts is executed, the equipment will return to the procedure of connecting to primary
server.
6.1.4.5.
Time for disconnection
If you check this box, the equipment will disconnect the secondary server after a defined
time. The following operation depends on the Connection sequence parameter (refer to
7.1.3.5). If the option is active the equipment will try to connect to primary server. In
case the option is inactive, the equipment will complete the procedure of connecting to
secondary server first, and in case it is unsuccessful, it will move on to attempting the
connection with primary server.
6.1.5.
Access
6.1.5.1.
Service code
It secures the equipment against unauthorized access. It is used for both, equipment
programming and for its remote control (in TCP/IP or SMS mode). Default factory setting