CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
52 / 144
EN
Setting the name of partition,
zone, outputs, users and system
Format
XXXX SETNAME=ELEMENT,[NR],VALUE_without_spaces
XXXX SETNAME=”ELEMENT,[NR],VALUE_with_spaces”
Command description
XXXX – service code (ATS) or admin code or installer code
(administrator has to grant him necessary permission
first)
Setting the name (position VALUE) for the item (a value
items below) number nr.
XXXX – service code or admin code or installer code
(administrator has to grant him necessary permission
first). Possible values position
ELEMENT:
PARTITION - Setting the name of partition; numbers 1
and 2
ZONE - Setting the name of input zone unit corresponding
to the indicated number; the numbers from 1 to 32
OUTPUT - Setting the name of output corresponding to
the indicated number; the numbers from 1 to 3
USER - Setting the name of user with the specified
number; the numbers from 1 to 32
SYSTEM - Setting the name of object which panel and
alarm system were installed. Note: here position “nr”
does not exist.
Example 1:
1234 SETNAME=PARTITION,1,Cellar
Example 2:
1234 SETNAME="PARTITION,2,Kids Room"
Feedback message
description
SETNAME:OK – command accepted
SETNAME:ERROR-PERMISSION - you do not have
permission to execute this command
SETNAME:ERROR-FORMAT - incorrect format command
SETNAME:ERROR-VALUE - incorrectly stated value
SETNAME:ERROR-PERMISSION - command rejected;
other errors