CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
53 / 144
EN
Getting the name of partition, zone, outputs, users and system
Format
XXXX GETNAME=ELEMENT,[NR]
Command description
Acquiring the name ofthe element with the specified
number nr. This command is complementary to SETNAME
- there are describes the permissible values of individual
fields, see the table "Setting the name of the partition,
inputs, outputs, users and system.
XXXX – service code (ATS) or admin code or installer code
(administrator has to grant him necessary permission
first)
Possible values position ELEMENT:
PARTITION - Acquiring the name of partition; numbers 1
and 2
ZONE - Acquiring the name of input zone unit
corresponding to the indicated number; the numbers
from 1 to 32
OUTPUT - Acquiring the name of output corresponding to
the indicated number; the numbers from 1 to 3
USER - Acquiring the name of user with the specified
number; the numbers from 1 to 32
SYSTEM - Acquiring the name of object which panel and
alarm system were installed. Note: here position “nr”
does not exist.
Example: 1234 GETNAME=PARTITION,1
Feedback message
description
GETNAME=ELEMENT,[NR],VALUE - command executed
correctly, the name of element
(NOTE: If the name has not been changed (remains the
default), it will not be given in the reply).
GETNAME:ERROR-PERMISSION - you do not have
permission to execute this command
GETNAME:ERROR-FORMAT - wrong format command
GETNAME:ERROR-VALUE – wrong value
GETNAME:ERROR-PERMISSION - command rejected;
other errors