CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
33 / 144
EN
5
– Alarms and inputs interlocking states are not displayed. If this option is enabled,
alarms and zone state are not displayed on the keypad. This option must be enabled
in order to comply with EN 50131 standard requirements for Grade 2.
6
– Temporary keyboard lock after three access failures. If this option is enabled, the
keypad will be blocked for 90 seconds, after entering an invalid code three times.
After this period, another lock will occur after entering a wrong code three times.
The counter of invalid codes will be reset after a correct code is entered (e.g. after
entering invalid code two times). This option must be enabled in order to comply
with EN 50131 standard requirements for Grade 2.
7
– Use duress code. Duress code is used to inform the monitoring station about a
distress event. Each user has his own duress code.
You can press
any time to exit without saving changes.
4.3.5.
Users remote management
That function allow to switch on or switch off remote users management. The argument of
the function is BIN type. By pressing key 1, you can switch on/off option. 3 beeps will
confirm the successfully entered function.
<Options>
Where:
Options
– number of option (BIN type parameter):
1
– enable/disable users remote management.
You can press
any time to exit without saving changes.
4.3.6.
Expanded system options
An additional system function used to turn individual options on or off. The argument of
this function is of the BIN type. 3 beeps will confirm the successfully entered function.
<Options>
Options
– option number:
1 –
Premises lock. This function turns off the ability to arm the control panel. When
this function is turned on, the user will not be able to arm the site by any way (i.e.
SMS/GPRS, remote, arming inputs, schedules, wired keypad, wireless keypad).
Disarming the system is possible, however. Attempts to arm will be rejected by the
control panel.
2 –
Defaults restoral lock. This function allows the user to turn off the ability to
restore the factory-default installation engineer code. However, when restoring
default settings using the Configuration, when the "Restore device’s default settings"
option is selected, a window with a request to enter the installer code or service
code (ATS) will appear.
When this function is turned on, the Manufacturer recommends that installer code
and service code (ATS) code are changed.