CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
60 / 144
EN
Define:
Connection name, e.g. Remote
Select analyzer name, e.g. primary
Enter analyzer name, e.g. www.ebs.pl
Enter the port on which analyzer will listen to instructions, e.g. 9000
Click [Add] button to confirm the setting. The connection is saved (and moved to the
table). From that moment the program will enable a remote connection with the
equipment and allows reading and saving the parameters in the equipment’s memory.
NOTE: Such parameters as: analyser’s name, analyser’s address, port
refer to the settings of the OSM.Server monitoring system receiver.
Remote programming is available only in case the above mentioned
equipment (software) is used.
CSD connection
The configuration of that mode requires activation of File option from Main Menu, and
selecting Connection function (or clicking
icon on a taskbar) and opening GSM Modem
tab.
The window will be displayed on the screen where you define:
Connection name, e.g. RemoteCSD
Serial port to which the GSM modem is connected to (e.g. COM1)
PIN code of SIM card installed in the GSM modem, e.g. 1111
Serial port parameters: Number of bits per second (e.g. 115200), Data Bits (8),
Parity (none), Stop Bits (1).
Click [Add] button to confirm the setting. The connection is saved (and moved to the
table). From that moment the program will enable a remote connection with the
equipment and allows reading and saving the parameters in the equipment’s memory.