CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
21 / 144
EN
12.
Partition 2 (“P2”)
The P2 symbol means partition 2, to which diodes from 1 to 8 are assigned.
13.
“GROUP” diode
When this diode is blinking quickly, it means entering the user function in which either
zones or users are shown.
14.
“ALARM” diode
When this diode is lit, it means a general system alarm (e.g. keypad sabotage, ALARM
button on the remote), where:
Blinks: alarm triggered in the past,
Lit continuously: current alarm.
15.
“SYSTEM” diode
When this diode is lit, it means a system failure, e.g.: power failure, battery failure,
ATS connection failure, power output failure, clock loss, keypad sabotage.
Blinks – it means that control panel memory stores failures that have passed,
Lit continuously – there is a failure in the system that has not been repaired,
Not lit – there are no failures in the system.
16.
“PROG” diode
Blinks slowly – the service function is enabled (a user function),
Blinks – data will be entered,
Lit continuously – installation engineer's service mode is enabled.
17.
Button 1 “P1”
A function button that supports the arming of partition P1.
18.
Button 2 “P2”
A function button that supports the arming of partition P2.
19.
Button 3 “P1+P2”
A function button that supports simultaneous arming of partitions P1 and P2.
20.
Button 5
(open padlock)
A function button that supports disarming.
21.
Button 7
(locked padlock)
A function button that supports the arming in full mode.
22.
Button 8
(moon)
A function button that supports the arming in night mode (SLEEP).
23.
Button 9
(sun)
A function button that supports the arming in day mode (STAY).
24.
Button “*”
(flame)