CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
118 / 144
EN
9.1.1.11.
DT
Format:
DT=YY/MM/DD,hh:mm
Limitations:
Data length of 14 characters, can be changed only by ATS or Administrator
Description
Sets date and hour
9.1.1.12.
SETMASK
Format:
SETMASK=id_typu,indeks,maska
Ograniczenia:
type_id must be 0, 1 or 2, command can be issued by ATS only
Opis
This is a low-level command which operates directly on the device
configuration memory. Sets mask bits in parameter
type_id,index
. This
command does not generate any events in addition to the information
that the configuration has been changed.
FOR:
SETMASK=0,65,0x01
Enable function
Premises lock
. This function turns off the ability to arm
the control panel. When this function is turned on, the user will not be
able to arm the site by any way (i.e. SMS/GPRS, remote, arming input,
schedules, keypad, wireless keypad). Disarming the system is possible,
however. Arming attempts will be rejected by the control panel.
SETMASK=2,19,0x100
Enable function
Defaults restoral lock
. This function allows the user to
turn off the ability to restore the factory-default installer’s code. However,
when restoring default settings using the Configuration, when the
"Restore device’s default settings" option is selected, a window with a
request to enter the installer’s code or service code (ATS) will appear.
NOTE: If you lose the newly set codes, you will need to send
blocked devices to EBS technical service.
SETMASK=2,19,0x400
Turning off the
Allow quick arming without user authorisation
function. After turning this function off, the system can only be armed if
an access code is entered.
9.1.1.13.
CLEARMASK
Format:
CLERMASK=id_typu,indeks,maska
Ograniczenia:
type_id must be 0, 1 or 2, command can be issued by ATS only