6.6.2.1.
For test and other events
It is possible to define two separate sets of additional data kinds: for test events (sent
periodically according to setting on Access tab) and for other events. Put a mark next to
the name of data kind to turn on transmission of this data kind to monitoring station.
Empty field means that this kind of data will be not transmitted.
The adjustable parameters are:
Power status – information about connected charger and battery charging
GSM status – status about connection to GSM network, type of connection to
server (GPRS/SMS), information about ongoing phone calls
GSM signal level quality – quality of connection to GSM network (CSQ and BER
parameters)
Battery voltage – voltage of battery in millivolt unit
6.6.2.2.
Contact ID
When transmitting data in the Contact ID format, in this section you can define individual
numbers for system account identification – ACN0, and its subsystems accounts, partition
1 – ACN1 and partition 2 – ACN2. This allows you to determine, which part of the system
the signal from.
NOTE: This option is available since the firmware version 2.9.0.
NOTE:
Numbers ACN0, ACN1 and ACN2 consist of four hexadecimal
characters.