9 Application Instructions API 150-199
DVP-PLC Application Manual
9-75
API Mnemonic
Operands
Function
190
MBC P
Matrix Bit Status Counting
Controllers
ES/EX/SS SA/SX/SC EH/SV
Bit Devices
Word Devices
Program Steps
Type
OP
X Y M S K H
KnX KnY KnM KnS T
C
D
E
F
S
*
*
*
*
*
*
*
n
*
*
*
D
*
*
*
*
*
*
*
*
MBC, MBCP: 7 steps
PULSE 16-bit 32-bit
ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV
Operands:
S
: Matrix source device
n
: Array length
D
: Counting result
Explanations:
1. Range
of
n
: K1 ~ K256
2.
S
designates KnX, KnY, KnM and KnS;
D
designates KnY, KnM and KnS.
3.
SA/SX/SC can designate n = 4. EH/EH2/SV can designate n
4
≦
.
4.
See the specifications of each model for their range of use.
5.
Flags: M1098, M1099. See remarks for more details.
6.
This instruction counts the number of bits which are “1” or “0” in
S
by array length
n
. The result is stored in
D
.
7.
The instruction counts the number of bits which are “1” when M1098 = 1 and counts the number of bits which
are “0” when M1098 = 0. When the operation result is “0”, M1099 = 1.
Program Example:
When X10 = On, in the matrix of D0 ~ D2, when M1098 = 1, the instruction counts the total number of bits which are
“1” and store the number in D10. When M1098 = 0, the instruction counts the total number of bits which are “0” and
store the number in D10.
X10
MBC
D0
K3
D10
1
1
1
1
1
1
0
1
1
1
1
1
1
1
0
1
0
1
1
1
1
1
1
0
1
0
0
12
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
M1098=0
36
M1098=1
Remarks:
Flag explanations:
Flags
Function
M1098
Counting the number of bits which are “1” or “0”
M1099
On when the counting result is “0”.
Содержание DVP-PLC
Страница 1: ...PLC PLC...
Страница 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Страница 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Страница 250: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 38 X0 DIV D0 D10 D20 D0 D10 K4Y0 DIV...
Страница 270: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 58 RST M0 X0 RST T0 RST Y0 FMOV K0 D10 K5...
Страница 337: ...7 Application Instructions API 50 99 DVP PLC APPLICATION MANUAL 7 53 X10 STMR T10 K50 Y0 Y3 X10 Y1 Y2 5 sec 5 sec...
Страница 458: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 56 or relay itself See 2 3 for more information...
Страница 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Страница 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...