9 Application Instructions API 150-199
DVP-PLC Application Manual
9-100
M1520
:
When On, CH2 pulse output will be forbidden.
M1521
:
When On, CH3 pulse output will be forbidden.
M1336
:
CH0 pulse output indication flag
M1337
:
CH1 pulse output indication flag
M1522
:
CH2 pulse output indication flag
M1523
:
CH3 pulse output indication flag
M1305
:
CH0 direction signal flag
M1306
:
CH1 direction signal flag
M1532
:
CH2 direction signal flag
M1533
:
CH3 direction signal flag
M1534
:
Deceleration time of CH0 setup flag (must used with D1348)
M1535
:
Deceleration time of CH1 setup flag (must used with D1349)
M1536
:
Deceleration time of CH2 setup flag (must used with D1350)
M1537
:
Deceleration time of CH3 setup flag (must used with D1351)
2. Special
register
explanations:
D1198
:
Close loop output/input ratio of CH0 (default: K100)
D1199
:
Close loop output/input ratio of CH1 (default: K100)
D1478
:
Close loop output/input ratio of CH2 (default: K100)
D1479
:
Close loop output/input ratio of CH3 (default: K100)
D1220
:
Phase setting of CH0 (Y0, Y1): determined by the last 2 digits of D1220; other digits are invalid.
1. K0: Y0 output
2. K1: Y0, Y1 AB-phase output; A ahead of B
3. K2: Y0, Y1 AB-phase output; B ahead of A
D1221
:
Phase setting of CH1 (Y2, Y3): determined by the last 2 digits of D1221; other digits are invalid.
1. K0: Y2 output
2. K1: Y2, Y3 AB-phase output; A ahead of B
3. K2: Y2, Y3 AB-phase output; B ahead of A
D1229
:
Phase setting of CH2 (Y4, Y5): determined by the last 2 digits of D1229; other digits are invalid.
1. K0: Y4 output
2. K1: Y4, Y5 AB-phase output; A ahead of B
3. K2: Y4, Y5 AB-phase output; B ahead of A
D1230
:
Phase setting of CH3 (Y6, Y7): determined by the last 2 digits of D1230; other digits are invalid.
1. K0: Y6 output
2. K1: Y6, Y7 AB-phase output; A ahead of B
3. K2: Y6, Y7 AB-phase output; B ahead of A
D1222
:
Time difference between the direction signal and pulse output of CH0
D1223
:
Time difference between the direction signal and pulse output of CH1
D1383
:
Time difference between the direction signal and pulse output of CH2
D1384
:
Time difference between the direction signal and pulse output of CH3
Содержание DVP-PLC
Страница 1: ...PLC PLC...
Страница 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Страница 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Страница 250: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 38 X0 DIV D0 D10 D20 D0 D10 K4Y0 DIV...
Страница 270: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 58 RST M0 X0 RST T0 RST Y0 FMOV K0 D10 K5...
Страница 337: ...7 Application Instructions API 50 99 DVP PLC APPLICATION MANUAL 7 53 X10 STMR T10 K50 Y0 Y3 X10 Y1 Y2 5 sec 5 sec...
Страница 458: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 56 or relay itself See 2 3 for more information...
Страница 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Страница 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...