9 Application Instructions API 150-199
DVP-PLC Application Manual
9-93
API Mnemonic Operands
Function
196
HST P
High Speed Timer
Controllers
ES/EX/SS SA/SX/SC EH/SV
Bit Devices
Word Devices
Program Steps
Type
OP
X Y M S K H
KnX KnY KnM KnS T
C
D
E
F
S
*
*
HST, HSTP: 3 steps
PULSE 16-bit 32-bit
ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV
Operands:
S
: Condition to stop the startup of high speed timer
Explanations:
1. Range
of
S
: S = K0 (H0), K1 (H1).
2. Flag:
M1015
3. When
S
= 1, the high speed timer will be enabled and M1015 = On. The high speed timer starts to time and
record the present value in D1015 (min. unit: 100us).
4.
Timing range of D1015: K0 ~ K32,767. When the timing reaches K32,767, the next timing will restart from 0.
5. When
S
= 0, the high speed timer will be disabled and M1015 = Off. D1015 will stop the timing immediately.
6. When
S
is neither 1 nor 0, HST instruction will not be executed.
Program Example :
1.
When X10 = On, M1015 will be On. The high speed timer will start to time and record the present value in
D1015.
2.
When X10 = Off, M1015 will be Off. The high speed timer will be shut down.
X10
HST
K1
X10
HST
K0
Remarks:
1. Flag
explanations:
M1015: high speed timer start-up flag
D1015: high speed timer
2.
EH/EH2/SV series MPU do not use this instruction and use special M and special D directly for the timer.
a) Special M and special D are only applicable when PLC RUN.
b) When M1015 = On and PLC scans to END instruction, the high speed timer D1015 will be enabled. The
minimum timing unit of D1015: 100us.
c) Timing range of D1015: K0 ~ K32,767. When the timing reaches K32,767, the next timing will restart from
K0.
d) When M1015 = Off, D1015 will stop the timing when encountering END or HST instruction.
3.
SA/SX/SC series MPU do not use this instruction and use special M and special D directly for the timer.
a) Special M and special D are applicable when PLC RUN or STOP.
Содержание DVP-PLC
Страница 1: ...PLC PLC...
Страница 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Страница 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Страница 250: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 38 X0 DIV D0 D10 D20 D0 D10 K4Y0 DIV...
Страница 270: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 58 RST M0 X0 RST T0 RST Y0 FMOV K0 D10 K5...
Страница 337: ...7 Application Instructions API 50 99 DVP PLC APPLICATION MANUAL 7 53 X10 STMR T10 K50 Y0 Y3 X10 Y1 Y2 5 sec 5 sec...
Страница 458: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 56 or relay itself See 2 3 for more information...
Страница 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Страница 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...