2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-105
b) After enabling MODEM (M1184 = On), PLC has to initialize MODEM first (M1185 = On). If PLC fails to
initialize MODEM, the auto-answering function of the MODEM will not be enabled.
c) After MODEM is initialized, it will enter auto-answering mode automatically.
d) If the remote PC is disconnected, MODEM will enter stand-by mode automatically and if the user turns off
MODEM now, MODEM will have to be initialized again when it is turned on again.
e) The connection speed is set by PLC as 9,600bps fixed and modification on the speed is not allowed.
MODEM has to be able to support the speed of 9,600bps and above.
f) The initialization format from PLC to MODEM are ATZ and ATS0 = 1.
g) If PLC fails to initialize MODEM, use the super terminal in PC to initialize it by the format ATZ and ATS0 = 1.
Function Group
Latched Area
Number
D1200 ~ D1219
Contents:
1.
The latched area for EH/EH2/SV/SA/SX/SC is from the start address No. to the end address No.
2.
See the tables in Chapter 2.1 for more details.
Function Group
Force On/Off of Input Point X
Number
M1304
Contents:
1.
For SA/SX/SC, when M1304 = On, peripheral devices, e.g. WPLSoft or HPP, can force On/Off of X0 ~ X17, but
the hardware LED will not respond to it.
2.
For EH/EH2/SV, when M1304 = On, peripheral devices, e.g. WPLSoft or HPP, can force On/Off of input point X,
and the hardware LED will respond to it.
Function Group
High-speed Output Pulse Stop Mode
Number
M1310 ~ M1311, M1334 ~ M1335, D1166 ~ D1167, D1343 ~ D1353
Contents:
1. Special D and special M for high-speed pulse output stop mode: (SC_V1.4 and versions above are with an
additional mode 3)
Device No.
Function
M1334
Select stop mode for Y10 pulse
M1335
Select stop mode for Y11 pulse
M1310
Immediately stop Y10 pulse output
M1311
Immediately stop Y11 pulse output
D1166
X10 rising-edge/falling-edge counting mode switch
D1167
X11 rising-edge/falling-edge counting mode switch
D1343 Acceleration/deceleration
time for Y10 pulse output
D1353
Acceleration/deceleration time for Y11 pulse output
2. How do Y10 pulse output stop modes work:
Содержание DVP-PLC
Страница 1: ...PLC PLC...
Страница 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Страница 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Страница 250: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 38 X0 DIV D0 D10 D20 D0 D10 K4Y0 DIV...
Страница 270: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 58 RST M0 X0 RST T0 RST Y0 FMOV K0 D10 K5...
Страница 337: ...7 Application Instructions API 50 99 DVP PLC APPLICATION MANUAL 7 53 X10 STMR T10 K50 Y0 Y3 X10 Y1 Y2 5 sec 5 sec...
Страница 458: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 56 or relay itself See 2 3 for more information...
Страница 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Страница 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...