2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-39
Special
M
Function
ES
EX
SS
SA
SX
SC
EH
EH2
SV
Off
Ø
On
STOP
Ø
RUN
RUN
Ø
STO
P
Attribute Latched Default
M1134*
Special high-speed pulse output Y0 (50KHz)
On: continuous output
(Not available in SC_V1.4 and above)
╳
○
╳
Off
Off
- R/W NO Off
M1135*
Special high-speed pulse output Y0 (50KHz)
reaches the target number of pulses.
SC_V1.4 and above: 2-axis synchronous control,
enabling Y11 output
╳
○
╳
Off
Off
Off R/W NO Off
M1136* Retaining the communication setting of COM3
╳
╳
○
Off
- - R/W NO Off
M1138*
Retaining the communication setting of COM1
(RS-232), modifying D1036 will be invalid when
M1138 is set.
○
○
○
Off
- - R/W NO Off
M1139*
Selecting ASCII or RTU mode of COM1 (RS-232)
when in Slave mode
Off: ASCII; On: RTU
○
○
○
Off
- - R/W NO Off
M1140
MODRD/MODWR/MODRW data receiving error
○
○
○
Off
Off
- R NO
Off
M1141
MODRD/MODWR/MODRW parameter error
○
○
○
Off
Off
- R NO
Off
M1142
Data receiving of VFD-A commands error
○
○
○
Off
Off
- R NO
Off
M1143*
Selecting ASCII or RTU mode of COM2 (RS-485)
when in Slave mode
Off: ASCII; On: RTU
Selecting ASCII or RTU mode of COM2 (RS-485)
when in Master mode (used together with MODRD/
MODWR/MODRW instructions)
Off: ASCII; On: RTU
○
○
○
Off
- - R/W NO Off
M1144*
Switch for enabling adjustable pulse
accelerating/decelerating output Y0
╳
○
╳
Off
Off
Off R/W NO Off
M1145* Adjustable pulse output Y0 is accelerating
╳
○
╳
Off
Off
- R/W NO Off
M1146*
Adjustable pulse output Y0 reaches the target
frequency
╳
○
╳
Off
Off
- R/W NO Off
M1147* Adjustable pulse output Y0 is decelerating
╳
○
╳
Off
Off
- R NO
Off
M1148* Adjustable pulse output Y0 is completed
╳
○
╳
Off
Off
Off R/W NO Off
M1149*
Adjustable pulse output Y0 temporarily stops
counting the number of pulses.
╳
○
╳
Off
Off
- R/W NO Off
M1150
DHSZ instruction in multiple set values comparison
mode
╳
╳
○
Off
- - R/W NO Off
M1151
The execution of DHSZ multiple set values
comparison mode is completed.
╳
╳
○
Off
- - R NO Off
M1152
Setting up DHSZ instruction as frequency control
mode
╳
╳
○
Off
- - R/W NO Off
M1153
DHSZ frequency control mode has been executed.
╳
╳
○
Off
- - R NO Off
Содержание DVP-PLC
Страница 1: ...PLC PLC...
Страница 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Страница 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Страница 250: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 38 X0 DIV D0 D10 D20 D0 D10 K4Y0 DIV...
Страница 270: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 58 RST M0 X0 RST T0 RST Y0 FMOV K0 D10 K5...
Страница 337: ...7 Application Instructions API 50 99 DVP PLC APPLICATION MANUAL 7 53 X10 STMR T10 K50 Y0 Y3 X10 Y1 Y2 5 sec 5 sec...
Страница 458: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 56 or relay itself See 2 3 for more information...
Страница 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Страница 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...