9 Application Instructions API 150-199
DVP-PLC Application Manual
9-46
4.
Whenever X11 = On, RTC will perform a ±30 second correction. The correction is performed according to the
rules: When the second hand of RTC locates at 1 ~ 29, the second will be automatically reset to “0” and the
minute hand will remain at its location. When the second hand locates at 30 ~ 59, the second will be
automatically reset to “0” and the minute hand will increase by 1 minute.
X10
MOV
K03
D0
MOV
K2
D1
MOV
K8
D2
MOV
K19
D3
MOV
K15
D4
MOV
K27
D5
MOV
K30
D6
TWR
D0
M1017
X11
Year (2003)
Day (Tuesday)
Month (August)
Date
Hour
Minute
Second
Write the set time into RTC
30 seconds correction
Содержание DVP-PLC
Страница 1: ...PLC PLC...
Страница 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Страница 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Страница 250: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 38 X0 DIV D0 D10 D20 D0 D10 K4Y0 DIV...
Страница 270: ...6 Application Instructions API 00 49 DVP PLC Application Manual 6 58 RST M0 X0 RST T0 RST Y0 FMOV K0 D10 K5...
Страница 337: ...7 Application Instructions API 50 99 DVP PLC APPLICATION MANUAL 7 53 X10 STMR T10 K50 Y0 Y3 X10 Y1 Y2 5 sec 5 sec...
Страница 458: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 56 or relay itself See 2 3 for more information...
Страница 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Страница 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...