ASDA-M Chapter 6 Control Mode of Operation
Revision December, 2014
6-39
6.3.7 Resonance
Suppression
When resonance occurs, it is probably because the stiffness of the control system is too
strong or the response is too fast. Eliminating these two factors might improve the
situation. In addition, low-pass filter (parameter P2-25) and notch filter (parameter P2-23
and P2-24) are provided to suppress the resonance if not changing the control
parameters.
Related parameters:
P2-23
NCF1
Resonance Suppression (Notch filter)
(1)
Address: 022EH
022FH
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.3.7
Operational
Interface
:
Panel / Software
Communication
Default
:
1000
Control
Mode
:
ALL
Unit
:
Hz
Range
:
50 ~ 1000
Data Size
:
16bit
Format
:
DEC
Settings
:
The first setting value of resonance frequency. If P2-24 is set to 0,
this function is disabled. P2-43 and P2-44 are the second Notch
filter.
P2-24
DPH1
Resonance Suppression (Notch filter)
Attenuation Rate (1)
Address: 0230H
0231H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.3.7
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Control
Mode
:
ALL
Unit
:
dB
Range
:
0 ~ 32 (0: disable the function of Notch
filter)
Data Size
:
16bit
Format
:
DEC
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...