ASDA-M Chapter 8 Parameters
Revision December, 2014
8-47
P1-06
SFLT
Analog Speed Command (Low-pass
Filter)
Address: 010CH
010DH
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.3.3
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Control
Mode
:
S
Unit
:
ms
Range
:
0 ~ 1000 (0: disable this function)
Data Size
:
16bit
Format
:
DEC
Settings
:
0: Disabled
P1-07
TFLT
Analog Torque Command (Low-pass
Filter)
Address: 010EH
010FH
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.4.3
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Control
Mode
:
T
Unit
:
ms
Range
:
0 ~ 1000 (0: disable this function)
Data Size
:
16bit
Format
:
DEC
Settings
:
0: Disabled
P1-08
PFLT
Smooth Constant of Position
Command (Low-pass Filter)
Address: 0110H
0111H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.2.6
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...