ASDA-M Chapter 6 Control Mode of Operation
Revision December, 2014
6-5
Logic
Type
Logic Pulse Type
Forward
Reverse
0
Positive Log
ic
AB phase
pulse
CW and
CCW pulse
Pulse +
Symbol
1
Negative Lo
gic
AB phase
pulse
CW and
CCW pulse
Pulse +
Symbol
Pulse
Specification
Max. Input
Frequency
Minimum time width
T1
T2
T3
T4
T5
T6
High-speed
pulse
Differential
Signal
4Mpps 62.5ns
125ns
250ns
200ns 125ns 125ns
Low-speed
pulse
Differential
Signal
500Kpps 0.5
μ
s
1
μ
s 2
μ
s 2
μ
s 1
μ
s 1
μ
s
Open-
collector
200Kpps
1.25
μ
s
2.5
μ
s
5
μ
s 5
μ
s 2.5
μ
s 2.5
μ
s
Pulse Specification
Max. Input
Frequency
Voltage
Specification
Forward Current
High-speed
pulse
Differential Signal
4Mpps
5V
< 25mA
Low-speed
pulse
Differential Signal
500Kpps
2.8V ~ 3.7V
< 25mA
Open-collector
200Kpps
24V (Max.)
< 25mA
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...