Chapter 8 Parameters ASDA-M
8-44
Revision December, 2014
Settings
:
X: Disable / enable speed limit function
0: Disable speed limit function
1: Enable speed limit function (it is effective in T mode only)
Other: Reserved
Block diagram of speed limit setting:
P1-09(1)
P1-10(2)
P1-11(3)
Vref
SPD0
SPD1
(0)
Speed Limit
Command
Y: Disable / enable torque limit function
0: Disable torque limit function
1: Enable torque limit function (it is effective in PT
/
PR
/
S
mode)
Other: Reserved
Block diagram of torque limit setting:
P1-12(1)
P1-13(2)
P1-14(3)
Tref
TCM0
TCM1
(0)
Torque Limit
Command
When desiring to use torque limit function, users could use
parameter to set Y = 1 and limit the torque for good. Thus,
the user can save one DI setting. Also, users could enable or
disable the limit function via DI.TRQLM, which is a more
flexible way but would need to take one DI setting. Torque
limit can be enabled by P1-02 or DI.
DI.TCM0 and DI.TCM1 are for selecting the limiting source.
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...