ASDA-M Chapter 8 Parameters
Revision December, 2014
8-201
TYPE: 1 ~ 4 and E ~ F accept
DO.STP stop and software
limit.
INS: When executing this PR, it interrupts the previous one.
OVLP: Allow the overlap of the next path. The overlap is not
allowed in speed mode. When overlap happens in position
mode, DLY has no function.
AUTO: When PR procedure completes, the next
procedure will be loaded in automatically.
CMD: Refer to Chapter 7 for PR command description.
DLY: 0 ~ F, delay time number (4 BIT). The delay after
executing this PR. The external INS is invalid.
DLY (4)
Index P5-40 ~ P5-55
P6-03
PDAT1
PATH#1 Data
Address: 0606H
0607H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Control
Mode
:
PR
Unit
:
-
Range
:
-2147483648 ~ +2147483647
Data Size
:
32bit
Format
:
DEC
Settings
:
PATH# 1 Data
17B
31 ~
28
18B
27 ~
24
19B
23 ~
20
20B
19 ~
16
21B
15 ~
12
11 ~ 8 7 ~ 4
3 ~ 0
BIT
DATA (32 bit)
Property of P6-02; P6-03 corresponds to the target position of
P6-02 or jump to PATH_NO.
NOTE
PATH (procedure)
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...