ASDA-M Chapter 6 Control Mode of Operation
Revision December, 2014
6-41
P2-45
NCF3
Resonance Suppression (Notch filter)
(3)
Address: 025AH
025BH
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.3.7
Operational
Interface
:
Panel / Software
Communication
Default
:
1000
Control
Mode
:
ALL
Unit
:
Hz
Range
:
50 ~ 2000
Data Size
:
16bit
Format
:
DEC
Settings
:
The third group of mechanism resonance frequency setting value.
If set P2-46 to 0, this function will be disabled. P2-23 and P2-24
are the first group of resonance suppression (Notch filter).
P2-46
DPH3
Resonance Suppression (Notch filter)
Attenuation Rate (3)
Address: 025CH
025DH
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.3.7
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Control
Mode
:
ALL
Unit
:
dB
Range
:
0 ~ 32
Data Size
:
16bit
Format
:
DEC
Settings
:
The third group of resonance suppression (Notch filter)
attenuation rate. Set the value to 0 to disable the function of
Notch filter.
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...