ASDA-M Chapter 8 Parameters
Revision December, 2014
8-141
Settings
:
When the voltage of DC BUS is lower than P4-24*
2
, the
undervoltage alarm occurs.
P4-25
SFSW Special Function Switch
Address: 0432H
0433H
Parameter
Attribute
:
Parameter for individual axis
Related Section: -
Operational
Interface
:
Panel / Software
Communication
Default
:
0x00000000
Control
Mode
:
ALL
Unit
:
-
Range
:
0x00000000 ~ 0x00000001
Data Size
:
32bit
Format
:
HEX
Settings
:
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Software limit switch in
speed mode
Sofware limit switch in speed mode
0: In speed mode, disable software limit protection and show
alarms only
1: In speed mode, enable software limit protection and show
alarms