ASDA-M Chapter 8 Parameters
Revision December, 2014
8-45
P1-03
AOUT
Polarity Setting of Encoder Pulse
Output
Address: 0106H
0107H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.6.3
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Control
Mode
:
ALL
Unit
:
-
Range
:
0 ~ 0x13
Data Size
:
16bit
Format
:
HEX
Settings
:
Polarity of monitor analog output
0: MON1(+), MON2(+)
1: MON1(+), MON2(-)
2: MON1(-), MON2(+)
3: MON1(-), MON2(-)
Polarity of encoder pulse output
0: Forward output
1: Reverse output
P1-04
MON1
MON1 Analog Monitor Output
Proportion
Address: 0108H
0109H
Parameter
Attribute
:
Parameter for individual axis
Related Section
Section 6.6.3
Operational
Interface
:
Panel / Software
Communication
Default
:
100
Control
Mode
:
ALL
Unit
:
% (full scale)
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...