Chapter 8 Parameters ASDA-M
8-66
Revision December, 2014
P1-47
SPOK
Speed Reached (DO
:
SP_OK) Range
Address: 015EH
015FH
Parameter
Attribute
:
Parameter for individual axis
Related Section: -
Operational
Interface
:
Panel / Software
Communication
Default
:
10
Control
Mode
:
S / Sz
Unit
:
r/min
Range
:
0 ~ 300
Data Size
:
16bit
Format
:
DEC
Settings
:
When the deviation between speed command and motor
feedback speed is smaller than this parameter, then the digital
output DO.SP_OK
(
DO code is 0x19
)
is ON.
Block diagram:
1. Speed command: It is the command issued by the user (without
acceleration / deceleration), not the one of front end speed circuit.
Source: Analog voltage and register
2. Feedback speed: The actual speed of the motor and have gone through
the filter.
3. Obtain the absolute value.
4. DO.SP_OK will be ON when the absolute value of speed error is smaller
than P1-47, or it will be OFF. If P1-47 is 0, DO.SP_OK is always OFF.
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...