Chapter 8 Parameters ASDA-M
8-78
Revision December, 2014
P1-80
OVLPL
The setting of the overlap PR path
Address: 01A0H
01A1H
Parameter
Attribute
:
Parameter for three axes
Related Section: -
Operational
Interface
:
Panel / Software
Communication
Default
:
100000
Control
Mode
:
PR
Unit
:
-
Range
:
1000 ~ 2147483647
Data Size
:
32bit
Format
:
DEC
Settings
:
This parameter is for setting the
deceleration area of previous path during
the PR path overlap.