![Delta ASD-M-0721 Series Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/delta/asd-m-0721-series/asd-m-0721-series_user-manual_2474520113.webp)
Chapter 5 Trial Operation and Tuning ASDA-M
5-10
Revision December, 2014
Please refer to Chapter 3.9.2, Position (PR) Mode Standard Wiring for wiring diagram.
However, since POS2 is not the default digital input, set P2-14 to 113. Please refer to the
table below for 64 sets of register command, POS0~POS5 and the relative parameters.
Position
Command
POS5 POS4 POS3
POS2
POS1
POS0
CTRG
Corresponding
Parameter
P1 0 0 0 0 0 0
P6-00
P6-01
P2 0 0 0 0 0 1
P6-02
P6-03
~
~
P50 1 1 0 0 1 0
P6-98
P6-99
P51 1 1 0 0 1 1
P7-00
P7-01
~
~
P64 1 1 1 1 1 1
P7-26
P7-27
0: means DI is OFF
1: means DI is ON
Users can set the 64-set of command value (P6-00~P7-27). The value can be set as the
absolute position command.
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...