Chapter 6 Control Mode of Operation ASDA-M
6-24
Revision December, 2014
6.3 Speed
Mode
Speed control mode (S or Sz) is applicable in precision speed control, such as CNC
machine tools. This servo drive includes two types of command input, analog and register.
Analog command input can use external voltage to control the motor speed. There are two
methods in register input. One is used before operation. Users set different value of speed
command in three registers, and then use SP0, SP1 of CN1 DI signal for switching. Another
method is to change the value of register by communication. In order to deal with the
problem of non-continuous speed command when switching register, a complete S-curve
program is provided. In close-loop system, this servo drive adopts gain adjustment and
integrated PI controller and two modes (manual and auto) for selection.
Users can set all parameters and all auto or auxiliary function will be disabled in manual
mode. While in auto mode, it provides the function of load inertia estimation and parameter
adjustment. In auto mode, parameters which set by users will be regarded as the default
value.
6.3.1 Selection of Speed Command
There are two types of speed command source, analog voltage and internal parameters.
The selection is determined by CN1 DI signal. See as the followings.
Speed
Command
No.
CN1 DI Signal
Command Source
Content
Range
SPD1 SPD0
S1 0 0
Mode
S
External
analog
command
Voltage deviation
between V-REF
and GND
-10 V ~ +10V
Sz N/A
Speed command
is 0
0
S2 0 1
Register parameters
P1-09
-60000 ~ 60000
S3
1
0
P1-10
-60000 ~ 60000
S4
1
1
P1-11
-60000 ~ 60000
Status of SPD0 ~ SPD1: 0 means DI OFF, 1 means DI ON.
When both SPD0 and SPD1 are 0, if it is in Sz mode, the command will be 0. Thus, if
there is no need to use analog voltage as the speed command, Sz mode can be
applied to tackle the problem of zero-drift. If it is in S mode, the command will be the
voltage deviation between V-REF and GND. The range of input voltage is between
-10V and +10V and its corresponding speed is adjustable (P1-40).
When one of SPD0 and SPD1 is not 0, the speed command is from the internal
parameter. The command is activated after changing the status of SPD0~SPD1.
There is no need to use CTRG for triggering.
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...