Setting Value: 0x10
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
OLW
When reaching the overload setting, this DO is ON.
t
OL
= Overload allowable time of the servo x Setting value of
P1-56, when the overload accumulative time exceeds
t
OL,
it will output pre-overload warning (OLW). However,
if the overload accumulative time exceeds the overload
allowable time of the servo, it will output pre-overload
error (ALRM).
For example:
The setting value of pre-overload warning is 60% (P1-56=60).
When the output average load of the servo drive is 200%, if
the output time exceeds 8 seconds, the servo drive will show
the overload alarm (ALE06).
t
OL
= The output average load of the servo exceeds 200% for
8 seconds x parameter setting value = 8sec x 60% =
4.8sec
Result: When the output average load of the servo drive
exceeds 200% for 4.8 seconds, this DO is ON. If it exceeds
for 8 seconds, then, DO, ALRM is ON.
Level
triggered
ALL
Setting Value: 0x11
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
WARN Warning output (Forward / reverse limit, communication
error, undervoltage, abnormal fan)
Level
triggered
ALL
Setting Value: 0x12
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
OVF
Position Command Overflows
Level
triggered
PR
Setting Value: 0x13
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
SNL
Software limit (Reverse limit)
Level
triggered
ALL
Setting Value: 0x14
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
SPL
Software limit (Forward limit)
Level
triggered
ALL
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...