Settings
:
bit 00: correspond to DO code=0x30
bit 01: correspond to DO code=0x31
bit 02: correspond to DO code=0x32
bit 03: correspond to DO code=0x33
bit 04: correspond to DO code=0x34
bit 05: correspond to DO code=0x35
bit 06: correspond to DO code=0x36
bit 07: correspond to DO code=0x37
bit 08: correspond to DO code=0x38
bit 09: correspond to DO code=0x39
bit 10: correspond to DO code=0x3A
bit 11: correspond to DO code=0x3B
bit 12: correspond to DO code=0x3C
bit 13: correspond to DO code=0x3D
bit 14: correspond to DO code=0x3E
bit 15: correspond to DO code=0x3F
When setting the DO number of each axis, please add the axial
parameter.
For example:
Each axis is used individually:
P2-18 of X axis is set to 0x1130, then the DO#1 of X axis is bit 0
status of P4-06 of X axis.
P2-18 of Y axis is set to 0x2130, then the DO#1 of Y axis is bit 0
status of P4-06 of Y axis.
P2-18 of Z axis is set to 0x3130, then the DO#1 of Z axis is bit 0
status of P4-06 of Z axis.
Each axis can be used one another: The DO status can be output
through P4-06 from other axes.
P2-18 of X axis is set to 0x2130, then the DO#1 of X axis is bit 0
status of P4-06 of Y axis.
P2-18 of Y axis is set to 0x3130, then the DO#1 of Y axis is bit 0
status of P4-06 of Z axis.
P2-18 of Z axis is set to 0x1130, then the DO#1 of Z axis is bit 0
status of P4-06 of X axis.
DO Code (0x30~0x3F) can be set via communication DO, and
then write into P4-06.
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...