
BigIron RX Series Configuration Guide
879
53-1002253-01
Globally configuring IS-IS on a device
28
The padding consists of arbitrarily valued octets. A padded hello PDU indicates the largest PDU that
the device can receive. Other ISs that receive a padded hello PDU from the device can therefore
ensure that the IS-IS PDUs they send the device. Similarly, if the device receives a padded hello
PDU from a neighbor IS, the device knows the maximum size PDU that the
device
can send to the
neighbor.
When padding is enabled, the maximum length of a Hello PDU sent by the
device
is 1514 bytes.
If you need to disable padding, you can do so globally or on individual interfaces. Generally, you do
not need to disable padding unless a link is experiencing slow performance. If you enable or
disable padding on an interface, the interface setting overrides the global setting.
To globally disable padding of IS-IS hello PDUs, enter the following command.
BigIron RX(config-isis-router)# no hello padding
This command disables all hello PDU padding on the
device
. To re-enable padding, enter the
following command.
BigIron RX(config-isis-router)# hello padding
Syntax: [no] hello padding
By default, hello padding is enabled. Enter the no form of the command to disable hello padding.
To disable hello padding on an interface, refer to
“Disabling and enabling hello padding on an
interface”
on page 888.
Logging adjacency changes
The
device
can generate a Syslog entry and an SNMP trap to indicate a change in the status of
an adjacency with another IS. Logging of the adjacency changes is disabled by default. To enable or
disable them, use either of the following methods.
To enable logging of adjacency changes, enter the following command.
BigIron RX(config-isis-router)# log-adjacency-changes
Syntax: [no] log-adjacency-changes
To disable logging of adjacency changes, enter the following command.
BigIron RX(config-isis-router)# no log-adjacency-changes
Disabling partial SPF calculations
By default, IS-IS makes incremental changes to the routing table when changes to the network
occur. A full SPF calculation is not performed unless there is a substantial change in the network;
for example when an IS-IS link flaps in the network. You can optionally configure IS-IS to perform a
full SPF calculation when any changes occur in the network.
To disable partial SPF calculations for IS-IS, enter the following command.
BigIron RX(config-isis-router)# disable-partial-spf-opt
Syntax: [no] disable-partial-spf-opt
Содержание BigIron RX Series
Страница 100: ...24 BigIron RX Series Configuration Guide 53 1002253 01 Logging on through the Web Management Interface 2 ...
Страница 192: ...116 BigIron RX Series Configuration Guide 53 1002253 01 Configuring authentication method lists 4 ...
Страница 228: ...152 BigIron RX Series Configuration Guide 53 1002253 01 Enabling WAN PHY mode support 6 ...
Страница 312: ...236 BigIron RX Series Configuration Guide 53 1002253 01 Displaying IP information 7 ...
Страница 356: ...280 BigIron RX Series Configuration Guide 53 1002253 01 Resetting LLDP statistics 9 ...
Страница 402: ...326 BigIron RX Series Configuration Guide 53 1002253 01 Transparent firewall mode 11 ...
Страница 432: ...356 BigIron RX Series Configuration Guide 53 1002253 01 SuperSpan 12 ...
Страница 500: ...424 BigIron RX Series Configuration Guide 53 1002253 01 MRP CLI example 14 ...
Страница 580: ...504 BigIron RX Series Configuration Guide 53 1002253 01 Configuring multicast traffic engineering 18 ...
Страница 591: ...BigIron RX Series Configuration Guide 515 53 1002253 01 Displaying traffic reduction 19 ...
Страница 592: ...516 BigIron RX Series Configuration Guide 53 1002253 01 Displaying traffic reduction 19 ...
Страница 598: ...522 BigIron RX Series Configuration Guide 53 1002253 01 Viewing Layer 2 ACLs 20 ...
Страница 656: ...580 BigIron RX Series Configuration Guide 53 1002253 01 Trunk formation 22 ...
Страница 754: ...678 BigIron RX Series Configuration Guide 53 1002253 01 Displaying RIP filters 24 ...
Страница 814: ...738 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPF information 25 ...
Страница 932: ...856 BigIron RX Series Configuration Guide 53 1002253 01 Generalized TTL security mechanism support 26 ...
Страница 980: ...904 BigIron RX Series Configuration Guide 53 1002253 01 Clearing IS IS information 28 ...
Страница 1000: ...924 BigIron RX Series Configuration Guide 53 1002253 01 Using secure copy 30 ...
Страница 1088: ...1012 BigIron RX Series Configuration Guide 53 1002253 01 IP source guard 35 ...
Страница 1108: ...1032 BigIron RX Series Configuration Guide 53 1002253 01 Reading CDP packets 37 ...
Страница 1126: ...1050 BigIron RX Series Configuration Guide 53 1002253 01 Clearing sFlow statistics 39 ...
Страница 1140: ...1064 BigIron RX Series Configuration Guide 53 1002253 01 802 1s Multiple Spanning Tree Protocol 40 ...
Страница 1324: ...1248 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPFv3 information 48 ...
Страница 1363: ...BigIron RX Series Configuration Guide 1287 53 1002253 01 Continuous System Monitor 51 ...
Страница 1364: ...1288 BigIron RX Series Configuration Guide 53 1002253 01 Continuous System Monitor 51 ...
Страница 1404: ...1328 BigIron RX Series Configuration Guide 53 1002253 01 Commands That Require a Reload D ...
Страница 1458: ...1382 BigIron RX Series Configuration Guide 53 1002253 01 VSRP E ...