
508
BigIron RX Series Configuration Guide
53-1002253-01
Configuring rate limiting policies
19
•
ACL-based rate limiting policies consume entries based on the number of statements in an
ACL.
•
See the limits in
Table 100
.
.
Configuring rate limiting policies
Configuring rate-limiting policies involves using the rate-limit command and specifying the
requested rate and maximum burst at the interface level of the CLI.
Software release 02.4.00 adds rate limiting to outbound ports.
Configuring a port-based rate limiting policy
Only one port-based rate limiting policy can be applied to an inbound port.
To configure a port-based rate limiting policy, enter commands such as the following.
BigIron RX(config)# interface ethernet 1/1
BigIron RX(config-if-e1000-1/1)# rate-limit out 500000000 750000000
Average rate is adjusted to 499639656 bits per second
The commands configure a rate limiting policy for outbound traffic on port 1/1. The policy requests
to limit the rate on all outbound traffic to 500 Mbps with a maximum burst size of 750 Mbps. The
device adjusts the requested rate to 499639656 bits per second.
Syntax: [no] rate-limit input | output <requested-rate> <maximum-burst>
Input applies rate limiting to inbound traffic on the port. Input can be abbreviated as in.
Output applies rate limiting to outbound traffic on the port. Output can be abbreviated as out.
Notes:
•
For outbound ports with slow speed links (for example, GbE), the rate supported is in
0.65Mbps increments, starting with 0.65 Mbps. That is, supported rates are 0.65 Mbps,
1.3 Mbps, 1.95 Mbps, etc.
•
For 10GbE ports, the rate supported is in 10.375 Mbps increments, starting with
10.375Mbps. That is, supported rates are 10.375 Mbps, 20.75 Mbps, 31.125 Mbps, etc.
TABLE 100
Maximum # of rate limiting policies and VLANs w/ byte accounting permitted
per-PPCR
Module type
PPCR number
Port #
Max # of rate limiting policies based on ACLs and
VLANs + number of VLANs w/ byte accounting
enabled
4 x 10G
PPCR 1
1
126
PPCR 2
2
126
PPCR 3
3
126
PPCR 4
4
126
24 x 1G
PPCR 1
1 - 12
115
PPCR 2
13 - 24
115
Содержание BigIron RX Series
Страница 100: ...24 BigIron RX Series Configuration Guide 53 1002253 01 Logging on through the Web Management Interface 2 ...
Страница 192: ...116 BigIron RX Series Configuration Guide 53 1002253 01 Configuring authentication method lists 4 ...
Страница 228: ...152 BigIron RX Series Configuration Guide 53 1002253 01 Enabling WAN PHY mode support 6 ...
Страница 312: ...236 BigIron RX Series Configuration Guide 53 1002253 01 Displaying IP information 7 ...
Страница 356: ...280 BigIron RX Series Configuration Guide 53 1002253 01 Resetting LLDP statistics 9 ...
Страница 402: ...326 BigIron RX Series Configuration Guide 53 1002253 01 Transparent firewall mode 11 ...
Страница 432: ...356 BigIron RX Series Configuration Guide 53 1002253 01 SuperSpan 12 ...
Страница 500: ...424 BigIron RX Series Configuration Guide 53 1002253 01 MRP CLI example 14 ...
Страница 580: ...504 BigIron RX Series Configuration Guide 53 1002253 01 Configuring multicast traffic engineering 18 ...
Страница 591: ...BigIron RX Series Configuration Guide 515 53 1002253 01 Displaying traffic reduction 19 ...
Страница 592: ...516 BigIron RX Series Configuration Guide 53 1002253 01 Displaying traffic reduction 19 ...
Страница 598: ...522 BigIron RX Series Configuration Guide 53 1002253 01 Viewing Layer 2 ACLs 20 ...
Страница 656: ...580 BigIron RX Series Configuration Guide 53 1002253 01 Trunk formation 22 ...
Страница 754: ...678 BigIron RX Series Configuration Guide 53 1002253 01 Displaying RIP filters 24 ...
Страница 814: ...738 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPF information 25 ...
Страница 932: ...856 BigIron RX Series Configuration Guide 53 1002253 01 Generalized TTL security mechanism support 26 ...
Страница 980: ...904 BigIron RX Series Configuration Guide 53 1002253 01 Clearing IS IS information 28 ...
Страница 1000: ...924 BigIron RX Series Configuration Guide 53 1002253 01 Using secure copy 30 ...
Страница 1088: ...1012 BigIron RX Series Configuration Guide 53 1002253 01 IP source guard 35 ...
Страница 1108: ...1032 BigIron RX Series Configuration Guide 53 1002253 01 Reading CDP packets 37 ...
Страница 1126: ...1050 BigIron RX Series Configuration Guide 53 1002253 01 Clearing sFlow statistics 39 ...
Страница 1140: ...1064 BigIron RX Series Configuration Guide 53 1002253 01 802 1s Multiple Spanning Tree Protocol 40 ...
Страница 1324: ...1248 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPFv3 information 48 ...
Страница 1363: ...BigIron RX Series Configuration Guide 1287 53 1002253 01 Continuous System Monitor 51 ...
Страница 1364: ...1288 BigIron RX Series Configuration Guide 53 1002253 01 Continuous System Monitor 51 ...
Страница 1404: ...1328 BigIron RX Series Configuration Guide 53 1002253 01 Commands That Require a Reload D ...
Страница 1458: ...1382 BigIron RX Series Configuration Guide 53 1002253 01 VSRP E ...