144
BigIron RX Series Configuration Guide
53-1002253-01
Port transition hold timer
6
NOTE
With the wait-for-all-cards command enabled,10G ports will come up before 1G ports because
Multi-Service IronWare software processes 10G port’s state changes first.
Port transition hold timer
Using the delay-link-event command will delay the sending of port "up" or "down" events to Layer 2
protocols. While link down events are reported immediately in syslog, their effect on higher level
protocols such as OSPF is delayed according to how the delay-link-event is configured. This
command affects the physical link events. However, the resulting logical link events are also
delayed. This is a per-interface command.
For example, if VSRP is enabled on the port, the ownership would not change until the port status
has remained up or down for the configured amount of time to ensure that minor transient states
of a link do not unintentionally cause a disruptive topology change in the network.
NOTE
All trunk ports must have the same delayed-link-down-event configuration.
The following command will delay the sending of port "down" event for 100ms when a port state is
detected "down". If the port state is detected "up" afterwards within 100ms, the delayed "down"
event is cancelled; otherwise, the "down" event is sent after 100ms. This allows the upper layer
applications not to be affected by a port state flapping.
BigIron RX (config-if-e1000-1/2)# delay-link-event 2 down
Syntax: delay-link-event <time> up | down
The <time> parameter is the number of 50-ms units. The default is 0.
The <up> parameter means only "up" events are delayed.
The <down> parameter means that only the down events are delayed.
Port flap dampening
The port flap dampening feature allows you to configure a wait period before a port, whose link
goes down then up, becomes enabled.
If the port flap state toggles (from down to up or from up to down) for a specified number of times
within a specified period, the interface is physically disabled for the specified wait period. Once the
wait period expires, the port’s link state is re-enabled. However, if the wait period is set to zero (0)
seconds, the port’s link state will remain disabled until it is manually re-enabled.
Configuration notes
•
When a link dampening port becomes a member of a trunk group, that port, as well as all other
member ports of that trunk group, will inherit the primary port’s configuration. This means
that the member ports will inherit the primary port’s link dampening configuration, regardless
of any previous configuration.
•
The Brocade device counts the number of times a port’s link state toggles from "up to down",
and not from "down to up".
Содержание BigIron RX Series
Страница 100: ...24 BigIron RX Series Configuration Guide 53 1002253 01 Logging on through the Web Management Interface 2 ...
Страница 192: ...116 BigIron RX Series Configuration Guide 53 1002253 01 Configuring authentication method lists 4 ...
Страница 228: ...152 BigIron RX Series Configuration Guide 53 1002253 01 Enabling WAN PHY mode support 6 ...
Страница 312: ...236 BigIron RX Series Configuration Guide 53 1002253 01 Displaying IP information 7 ...
Страница 356: ...280 BigIron RX Series Configuration Guide 53 1002253 01 Resetting LLDP statistics 9 ...
Страница 402: ...326 BigIron RX Series Configuration Guide 53 1002253 01 Transparent firewall mode 11 ...
Страница 432: ...356 BigIron RX Series Configuration Guide 53 1002253 01 SuperSpan 12 ...
Страница 500: ...424 BigIron RX Series Configuration Guide 53 1002253 01 MRP CLI example 14 ...
Страница 580: ...504 BigIron RX Series Configuration Guide 53 1002253 01 Configuring multicast traffic engineering 18 ...
Страница 591: ...BigIron RX Series Configuration Guide 515 53 1002253 01 Displaying traffic reduction 19 ...
Страница 592: ...516 BigIron RX Series Configuration Guide 53 1002253 01 Displaying traffic reduction 19 ...
Страница 598: ...522 BigIron RX Series Configuration Guide 53 1002253 01 Viewing Layer 2 ACLs 20 ...
Страница 656: ...580 BigIron RX Series Configuration Guide 53 1002253 01 Trunk formation 22 ...
Страница 754: ...678 BigIron RX Series Configuration Guide 53 1002253 01 Displaying RIP filters 24 ...
Страница 814: ...738 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPF information 25 ...
Страница 932: ...856 BigIron RX Series Configuration Guide 53 1002253 01 Generalized TTL security mechanism support 26 ...
Страница 980: ...904 BigIron RX Series Configuration Guide 53 1002253 01 Clearing IS IS information 28 ...
Страница 1000: ...924 BigIron RX Series Configuration Guide 53 1002253 01 Using secure copy 30 ...
Страница 1088: ...1012 BigIron RX Series Configuration Guide 53 1002253 01 IP source guard 35 ...
Страница 1108: ...1032 BigIron RX Series Configuration Guide 53 1002253 01 Reading CDP packets 37 ...
Страница 1126: ...1050 BigIron RX Series Configuration Guide 53 1002253 01 Clearing sFlow statistics 39 ...
Страница 1140: ...1064 BigIron RX Series Configuration Guide 53 1002253 01 802 1s Multiple Spanning Tree Protocol 40 ...
Страница 1324: ...1248 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPFv3 information 48 ...
Страница 1363: ...BigIron RX Series Configuration Guide 1287 53 1002253 01 Continuous System Monitor 51 ...
Страница 1364: ...1288 BigIron RX Series Configuration Guide 53 1002253 01 Continuous System Monitor 51 ...
Страница 1404: ...1328 BigIron RX Series Configuration Guide 53 1002253 01 Commands That Require a Reload D ...
Страница 1458: ...1382 BigIron RX Series Configuration Guide 53 1002253 01 VSRP E ...