BigIron RX Series Configuration Guide
53-1002253-01
Configuring additional VRRP and VRRPE parameters
17
•
For VRRP, the software changes the priority of the virtual router to a track priority that is lower
than that of the virtual router priority and lower than the priorities configured on the Backups.
For example, if the virtual router priority is 100 and a tracked interface with track priority 60
goes down, the software changes the virtual router priority to 60.
•
For VRRPE, the software reduces the virtual router priority by the amount of the priority of the
tracked interface that went down. For example, if the VRRPE interface’s priority is 100 and a
tracked interface with track priority 60 goes down, the software changes the VRRPE interface’s
priority to 40. If another tracked interface goes down, the software reduces the virtual router’s
priority again, by the amount of the tracked interface’s track priority.
The default track priority for a VRRP Owner is 2. The default track priority for Backups is 1.
You enter the track priority as a parameter with the owner or backup command. Refer to
“Track
port”
on page 465.
Syntax: owner [track-priority
<value>
]
Syntax: backup [priority
<value>
] [track-priority
<value>
]
The syntax is the same for VRRP and VRRPE.
Backup preempt
By default, a Backup that has a higher priority than another Backup that has become the Master
can preempt the Master, and take over the role of Master. If you want to prevent this behavior,
disable preemption.
Preemption applies only to Backups and takes effect only when the Master has failed and a
Backup has assumed ownership of the virtual router. The feature prevents a Backup with a higher
priority from taking over as Master from another Backup that has a lower priority but has already
become the Master of the virtual router.
Preemption is especially useful for preventing flapping in situations where there are multiple
Backups and a Backup with a lower priority than another Backup has assumed ownership, because
the Backup with the higher priority was unavailable when ownership changed.
If you enable the non-preempt mode (thus disabling the preemption feature) on all the Backups,
the Backup that becomes the Master following the disappearance of the Master continues to be
the Master. The new Master is not preempted.
NOTE
In VRRP, regardless of the setting for the preempt parameter, the Owner always returns to be the
Master when it comes back online.
To disable preemption on a Backup, enter commands such as the following.
Router1(config)# inter e 1/6
Router1(config-if-e10000-1/6)# ip vrrp vrid 1
Router1(config-if-e10000-1/6-vrid-1)# non-preempt-mode
Syntax: non-preempt-mode
The syntax is the same for VRRP and VRRPE.
Master router abdication and reinstatement
To change the Master’s priority, enter commands such as the following.
Содержание BigIron RX Series
Страница 100: ...24 BigIron RX Series Configuration Guide 53 1002253 01 Logging on through the Web Management Interface 2 ...
Страница 192: ...116 BigIron RX Series Configuration Guide 53 1002253 01 Configuring authentication method lists 4 ...
Страница 228: ...152 BigIron RX Series Configuration Guide 53 1002253 01 Enabling WAN PHY mode support 6 ...
Страница 312: ...236 BigIron RX Series Configuration Guide 53 1002253 01 Displaying IP information 7 ...
Страница 356: ...280 BigIron RX Series Configuration Guide 53 1002253 01 Resetting LLDP statistics 9 ...
Страница 402: ...326 BigIron RX Series Configuration Guide 53 1002253 01 Transparent firewall mode 11 ...
Страница 432: ...356 BigIron RX Series Configuration Guide 53 1002253 01 SuperSpan 12 ...
Страница 500: ...424 BigIron RX Series Configuration Guide 53 1002253 01 MRP CLI example 14 ...
Страница 580: ...504 BigIron RX Series Configuration Guide 53 1002253 01 Configuring multicast traffic engineering 18 ...
Страница 591: ...BigIron RX Series Configuration Guide 515 53 1002253 01 Displaying traffic reduction 19 ...
Страница 592: ...516 BigIron RX Series Configuration Guide 53 1002253 01 Displaying traffic reduction 19 ...
Страница 598: ...522 BigIron RX Series Configuration Guide 53 1002253 01 Viewing Layer 2 ACLs 20 ...
Страница 656: ...580 BigIron RX Series Configuration Guide 53 1002253 01 Trunk formation 22 ...
Страница 754: ...678 BigIron RX Series Configuration Guide 53 1002253 01 Displaying RIP filters 24 ...
Страница 814: ...738 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPF information 25 ...
Страница 932: ...856 BigIron RX Series Configuration Guide 53 1002253 01 Generalized TTL security mechanism support 26 ...
Страница 980: ...904 BigIron RX Series Configuration Guide 53 1002253 01 Clearing IS IS information 28 ...
Страница 1000: ...924 BigIron RX Series Configuration Guide 53 1002253 01 Using secure copy 30 ...
Страница 1088: ...1012 BigIron RX Series Configuration Guide 53 1002253 01 IP source guard 35 ...
Страница 1108: ...1032 BigIron RX Series Configuration Guide 53 1002253 01 Reading CDP packets 37 ...
Страница 1126: ...1050 BigIron RX Series Configuration Guide 53 1002253 01 Clearing sFlow statistics 39 ...
Страница 1140: ...1064 BigIron RX Series Configuration Guide 53 1002253 01 802 1s Multiple Spanning Tree Protocol 40 ...
Страница 1324: ...1248 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPFv3 information 48 ...
Страница 1363: ...BigIron RX Series Configuration Guide 1287 53 1002253 01 Continuous System Monitor 51 ...
Страница 1364: ...1288 BigIron RX Series Configuration Guide 53 1002253 01 Continuous System Monitor 51 ...
Страница 1404: ...1328 BigIron RX Series Configuration Guide 53 1002253 01 Commands That Require a Reload D ...
Страница 1458: ...1382 BigIron RX Series Configuration Guide 53 1002253 01 VSRP E ...