74
BigIron RX Series Configuration Guide
53-1002253-01
Setting up local user accounts
4
4. Enter no password at the prompt. (You cannot abbreviate this command.) This command will
cause the device to bypass the system password check.
5. Enter boot system flash primary at the prompt.
6. After the console prompt reappears, assign a new password.
Displaying the SNMP community string
If you want to display the SNMP community string, enter the following commands.
BigIron RX(config)# enable password-display
BigIron RX(config)# show snmp server
The enable password-display command enables display of the community string, but only in the
output of the show snmp server command. Display of the string is still encrypted in the startup
configuration file and running configuration. Enter the command at the global CONFIG level of the
CLI.
Disabling password encryption
When you configure a password, then save the configuration to the Brocade device’s flash memory,
the password is also saved to flash as part of the configuration file. By default, the passwords are
encrypted so that the passwords cannot be observed by another user who displays the
configuration file. Even if someone observes the file while it is being transmitted over TFTP, the
password is encrypted.
If you want to remove the password encryption, you can disable encryption by entering the following
command.
BigIron RX(config)# no service password-encryption
Syntax: [no] service password-encryption
Specifying a minimum password length
By default, the Brocade device imposes no minimum length on the Line (Telnet), Enable, or Local
passwords. You can configure the device to require that Line, Enable, and Local passwords be at
least a specified length.
For example, to specify that the Line, Enable, and Local passwords be at least 8 characters, enter
the following command.
BigIron RX(config)# enable password-min-length 8
Syntax: enable password-min-length <number-of-characters>
The <number-of-characters> can be from 1 – 48.
Setting up local user accounts
You can define up to 16 local user accounts on a device. User accounts regulate who can access
the management functions in the CLI using the following methods:
•
Telnet access
Содержание BigIron RX Series
Страница 100: ...24 BigIron RX Series Configuration Guide 53 1002253 01 Logging on through the Web Management Interface 2 ...
Страница 192: ...116 BigIron RX Series Configuration Guide 53 1002253 01 Configuring authentication method lists 4 ...
Страница 228: ...152 BigIron RX Series Configuration Guide 53 1002253 01 Enabling WAN PHY mode support 6 ...
Страница 312: ...236 BigIron RX Series Configuration Guide 53 1002253 01 Displaying IP information 7 ...
Страница 356: ...280 BigIron RX Series Configuration Guide 53 1002253 01 Resetting LLDP statistics 9 ...
Страница 402: ...326 BigIron RX Series Configuration Guide 53 1002253 01 Transparent firewall mode 11 ...
Страница 432: ...356 BigIron RX Series Configuration Guide 53 1002253 01 SuperSpan 12 ...
Страница 500: ...424 BigIron RX Series Configuration Guide 53 1002253 01 MRP CLI example 14 ...
Страница 580: ...504 BigIron RX Series Configuration Guide 53 1002253 01 Configuring multicast traffic engineering 18 ...
Страница 591: ...BigIron RX Series Configuration Guide 515 53 1002253 01 Displaying traffic reduction 19 ...
Страница 592: ...516 BigIron RX Series Configuration Guide 53 1002253 01 Displaying traffic reduction 19 ...
Страница 598: ...522 BigIron RX Series Configuration Guide 53 1002253 01 Viewing Layer 2 ACLs 20 ...
Страница 656: ...580 BigIron RX Series Configuration Guide 53 1002253 01 Trunk formation 22 ...
Страница 754: ...678 BigIron RX Series Configuration Guide 53 1002253 01 Displaying RIP filters 24 ...
Страница 814: ...738 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPF information 25 ...
Страница 932: ...856 BigIron RX Series Configuration Guide 53 1002253 01 Generalized TTL security mechanism support 26 ...
Страница 980: ...904 BigIron RX Series Configuration Guide 53 1002253 01 Clearing IS IS information 28 ...
Страница 1000: ...924 BigIron RX Series Configuration Guide 53 1002253 01 Using secure copy 30 ...
Страница 1088: ...1012 BigIron RX Series Configuration Guide 53 1002253 01 IP source guard 35 ...
Страница 1108: ...1032 BigIron RX Series Configuration Guide 53 1002253 01 Reading CDP packets 37 ...
Страница 1126: ...1050 BigIron RX Series Configuration Guide 53 1002253 01 Clearing sFlow statistics 39 ...
Страница 1140: ...1064 BigIron RX Series Configuration Guide 53 1002253 01 802 1s Multiple Spanning Tree Protocol 40 ...
Страница 1324: ...1248 BigIron RX Series Configuration Guide 53 1002253 01 Displaying OSPFv3 information 48 ...
Страница 1363: ...BigIron RX Series Configuration Guide 1287 53 1002253 01 Continuous System Monitor 51 ...
Страница 1364: ...1288 BigIron RX Series Configuration Guide 53 1002253 01 Continuous System Monitor 51 ...
Страница 1404: ...1328 BigIron RX Series Configuration Guide 53 1002253 01 Commands That Require a Reload D ...
Страница 1458: ...1382 BigIron RX Series Configuration Guide 53 1002253 01 VSRP E ...