System Configuration
SiBE811001EB
11
CONVENI-PACK
2.3
Features of Refrigerant System
Feature-1: Energy saving operation by controlling [3 evaporating temperatures] and [3 liquid refrigerant temperatures].
Feature-2: Energy saving operation by heat recovery of refrigeration system during heating operation.
Liquid temperature 35˚C
Pre-heat exchanger
Liquid temperature 0˚C
Liquid temperature 40˚C
Refrigeration showcase: 5˚C
Refrigeration showcase: 5˚C
Freezer showcase: -30˚C
Indoor unit for air conditioning
Evaporating
temperature 5˚C
Evaporating
temperature -10˚C
Liquid
temperature 20˚C
Evaporating
temperature -35˚C
Double pipe
heat exchanger
Plate type
heat exchanger
(Intermediate
pressure)
(a)
0
˚C
20
˚C
35
˚C
(b)
(d)
(f)
(e)
(g)
(c)
Pressure (MPa)
Enthalpy (kcal/kg)
Condensing temperature: 40
˚C
Compressor for freezer
Performs cooling of liquid
refrigerant from 35˚C (c) to 20˚C
(b) with this evaporating heat.
Performs cooling of liquid
refrigerant from 20˚C (b) to 0˚C
(a) with this evaporating heat.
<Plate type heat exchanger>
<Double pipe heat exchanger>
Saturation temperature equivalent of
intermediate pressure: 10˚C
Compressor for air conditioning
(with economizer)
Compressor for refrigeration
(with economizer)
Evaporating temperature at
air conditioning side: 0
˚C
Evaporating temperature
at refrigeration side: -10
˚C
Evaporating temperature
at freezer side: -35
˚C