LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Serial Interface Operation
Revision 5
8–9
8.3.3
ATT (Attenuation Level)
Command or query. Use “ATT” to set or return the attenuation level, in dB, in 0.1
dB steps.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
ATT_y_xx.xx
ATT_y_
7 bytes,
alphanumeric
Set or return in the form ATT_y_xx.xx where:
y=A (Conv A) or B (Conv B)
xx.xx=Valid attenuation level, in dB (0.1 dB step
size is factory default)
ATT_y_xx.xx ATT_y_ xx.xx
Command Example:
<0001/12.20{cr}
8.3.4
CAA (Clear All Alarms)
Command only. Use “CAA” to clear all stored alarms from the Target’s events
log.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
CAA_xxx{cr}
N/A
3 bytes,
alphabetic
Set or return in the form CAA_xxx where:
xxx=YES
CAA_CLEARED
N/A
Command Example:
<0001/CAA_YES{cr}
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...