Query Example:
<0001/SSN_U{cr}
>0001/SSN_U_012345678{cr}{lf}
8.3.41
TIM (Set RTC [Real-Time Clock] Time)
Command or Query. Use “TIM” to set or return the real-time clock time.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
TIM_
TIM_
8 bytes,
numeric
Set or return the time, in military/from midnight
format, in the form TIM_hh:mm:ss where:
hh:=hours from 00 to 23
mm:=minutes, from 00 to 59
ss=seconds, from 00 to 59
TIM_
TIM_hh:mm:ss
Command Example:
<0001/TIM_23:12:59{cr}
(Sets time from midnight to 23 hours, 12 minutes, 59
seconds, or 11:12:59 PM)
8.3.42
VFD (Set Vacuum Fluorescent Display Brightness)
Command or Query. Use “VFD” to set or return the brightness level for the front
panel display.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
VFD_
VFD_
1 byte, numeric,
value 0 to 3
Set or return the vacuum fluorescent display
brightness in the form VFD_x where:
x=0 (100%), 1 (75%), 2 (50%), or 3 (25%)
VFD_
VFD_x
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...