LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Specifications
Revision 5
2–6
2.1.8.5
Serial Connectors
•
Summary Alarm:
(1X) DB-9F (D-Subminiature)
‘P1 | Relay’
Utility
Connector to access the Form C Alarms (relay closures).
•
Serial Remote Control Interface:
(1X) DB-9F (D-Subminiature)
‘J1 |
COM1’
EIA-232/EIA-485 (2-Wire/4-Wire) connector.
2.1.8.6
Chassis Power and Grounding
2.1.8.6.1
Power Supply Input
•
STANDARD AC:
o
Two 100W power supplies with diode “OR-ed” outputs provide
the system supply voltages of +12VDC and +5VDC.
o
90-260VAC, 47-63 Hz frequency, nominal system power
consumption of 35W total dissipation (two up/down converter
IDU modules).
o
An IEC-60320 Type C13 (female) three-prong plug power cord for
90-125VAC or 205-240VAC power sources is provided with the
converter. This detachable power cord mates with the AC Prime
Power Module IEC-60320 Type C14 male connector on the rear of
the converter chassis.
•
OPTIONAL DC:
The DC Filter Input Module input voltage is 48VDC nominal, -36 VDC
minimum, -72VDC maximum.
2.1.8.6.2
Grounding
A #10-32 stud provides a common chassis ground connection among equipment.