background image

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

© Copyright 2008, American Fibertek, Inc. 0909JD 

 
 

Instruction Manual 

 

MX2-MM-FX-SC 

MXR2-MM-FX-SC 

MX2-SM-FX-SC 

MXR2-SM-FX-SC 

 Media Converter 

Содержание MX2-MM-FX-SC

Страница 1: ... Copyright 2008 American Fibertek Inc 0909JD Instruction Manual MX2 MM FX SC MXR2 MM FX SC MX2 SM FX SC MXR2 SM FX SC Media Converter ...

Страница 2: ...ower Source 4 MX2 Power Connection 4 MX2 Fiber Data Connections 4 MX2 Copper Data Connections 4 MXR2 Power Source 5 MXR2 Power Connection 5 MXR2 Fiber Data Connections 5 MXR2 Copper Data Connections 5 MX2 MXR2 Status LED Indicators 6 Warranty 7 Service Information 7 ...

Страница 3: ...tiate the copper ports to either 10Base T or 100Base TX Ethernet data at full or half duplex The auto negotiate feature also selects the proper MDI or MDIX interface The MX2 MXR2 series fiber port is set to 100Base FX and is compatible with IEEE802 3 100Base FX standard products The availability of both a copper and a fiber port allows the MX2 MXR2 series product to be used as a straight through E...

Страница 4: ...ive side of the power input is directly connected to ground ANSI NFPA 70 Class 2 wiring is recommended MX2 SERIES POWER CONNECTION Power is supplied to the MX2 series units via a connection on the right side of the unit refer to the drawing above MX2 SERIES FIBER DATA CONNECTIONS The fiber optic connections are made via SC connectors located on the left side of the unit The TX port of this unit is...

Страница 5: ...he MXR2 series units via a four finger backplane connector The MXR2 series units can be inserted into the subrack or removed from the subrack with power applied to the backplane MXR2 SERIES FIBER DATA CONNECTIONS The fiber optic connections are made via SC connectors located on the front of the unit The TX port of this unit is connected to the RX port of the corresponding unit MXR2 SERIES COPPER D...

Страница 6: ...ED is summarized below Link ACT1 Indicator Port 1 Status Solid Green Port 1 Connected Flashing Green Port 1 Communicating Off No Data Flow SPD1 A bi colored LED indicator monitors the speed of the data flow on RJ45 copper port 1 Data status associated with this LED is summarized below SPD1 Indicator Port 1 Status Green Port 1 Connected and in 100 Mbps Mode Amber Port 1 Connected and in 10 Mbps Mod...

Страница 7: ...ntract EXCEPT FOR THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In any event American Fibertek will not be responsible or liable for contingent consequential or incidental damages No agreement or understanding expressed or implied except as set forth ...

Отзывы: