Parameter Status
Product identification (i.e., CID/AID, serial and model numbers), active firmware,
software image information, and other operational configuration information is
provided here.
Converter A / Converter B Status
This section identifies the converter installed in each module slot (BUC or BDC)
and each module’s associated RF conversion band and frequency, attenuation
value, mute status, and online/offline status.
Converter A / B, PS (Power Supply) A / B, Monitor and Status
This section provides the current monitored value for each module (BUC or BDC),
including the RF/IF lockout status, operating voltages and temperatures. The
operating voltages for each power supply are also provided.
Note that:
1)
Valid Converter A/Converter B LNA Current readings are provided only if
the pertinent LBC-4000 Down Converter (BDC) is optionally configured
with an LNA. These parameters otherwise display as
N/A
if the pertinent
converter is a BUC.
2)
Valid Converter A/Converter B Forward RF Power readings are provided
only if the pertinent LBC-4000 up converter (BUC) is optionally configured
with the Power Monitor feature. These parameters otherwise display as
N/A
if the pertinent converter is a BDC.
3)
Valid Power Supply 2 and Local Switch Position information is provided
with redundant configurations only.
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...