LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Serial Interface Operation
Revision 5
8–18
8.3.25
RAS (Retrieve Alarm Status)
Query only. Use “RAS” to return the alarm status for the unit.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
N/A
RAS_
122 bytes,
alphanumeric
Return the detailed alarm status, where xx=OK (NO
FAULT) or FT (FAULT):
N/A
RAS_x…x
12VDC1_xx{cr}
08VDC1_xx{cr}
05VDC1_xx{cr}
12VDC2_xx{cr}
08VDC2_xx{cr}
05VDC2_xx{cr}
REFLD_xx{cr}
IFLOA_xx{cr}
RFLOA_xx{cr}
TEMPA_xx{cr}
IFLOB_xx{cr}
RFLOB_xx{cr}
TEMPB_xx{cr}{lf}
12VDC #1 Fault
8VDC #1 Fault
5VDC #1 Fault
12VDC #2 Fault
8VDC #2 Fault
5VDC #2 Fault
Ref Osc Lock Detect Fault*
Conv A IFLO Lock Detect Fault
Conv A RFLO Lock Detect Fault
Conv A Over Temperature Fault
Conv B IFLO Lock Detect Fault
Conv B RFLO Lock Detect Fault
Conv B Over Temperature Fault
*Note:
“REFLD” is returned only when an external reference is present.
8.3.26
RCS (Retrieve Configuration Status)
Query only. Use “RCS” to return the configuration status for the unit.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
N/A
RCS_
186 bytes,
alphanumeric
Return the detailed configuration status for the unit:
N/A
RCS_F...X
FRE_A_xxxxx.xxx
ATT_A_xx.xx
TX_A_yyy
SLP_A_x.x
ONL_A_yyy
FRE_B_xxxxx.xxx
ATT_B_xx.xx
TX_B_yyy
SLP_B_x.x
ONL_B_yyy
RED_yyy
AFR_yyy
EXT_yyy
REF_xxx
REM_yyy
COMM_RS-xxx
ADD_xxxx
BR_xxxx
FMT_X-X-X
Conv A frequency
Conv A attenuation
Conv A mute state
Conv A slope adjustment
Conv A ONline/OFFline
Conv B frequency
Conv B attenuation
Conv B mute state
Conv B slope adjustment
Conv B ONline/OFFline
Conv Redundancy ON/OFF
Auto Fault Recovery ON/OFF
External Reference YES/NO
Ref Osc Adjustment
Remote Mode YES/NO
Remote Interface RS-232/RS-485
Remote Address 0001-9999
Remote Baud Rate
Remote Data Format
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...