LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Serial Interface Operation
Revision 5
8–19
8.3.27
RED (Redundancy Mode)
Command or query. Use “RED” to set or return the active redundancy mode.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
RED_
RED_
3 bytes,
alphabetic
Set or return in the form RED_yyy where:
yyy=ON (Redundancy is enabled) or OFF
(Redundancy is disabled)
RED_
RED_
8.3.28
REM (Remote Mode)
Command or Query. Use “REM” to set or return the active operating mode as
Local or Remote.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
REM_
REM_
1 bytes,
numeric, 0 or 1
Set or return in the form REM_x where:
x=0 (Local Mode) or 1 (Remote Mode)
REM_
REM_x
Command Example:
<0001/REM_1{cr} (sets operation to Remote Mode)
8.3.29
RET (Retrieve Equipment Type)
Query only. Use “RET” without an argument to return the model number and
firmware version of the unit.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
N/A
RET_
22 bytes,
alphanumeric
Query, when used without argument, returns a
string in the form RET_LBC-4000_VER:X.X.X
where:
X.X.X=Firmware Version Number
N/A
RET_
Query Example:
<0001/RET_{cr}
>0001/RET_LBC-4000 VER:1.2.5{cr}{lf}
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...